Install ignition coil
- Install ignition coil (3).
- Tighten down screw (2).TIGHTENING TORQUE SPECIFICATIONS
Ignition coil Screw Tightening torque 8 Nm - Connect connectors (1) and lock.
The connector (1) must engage audibly.
- Attach connector (1) of the primary oxygen sensor and the monitoring oxygen sensor to the cable duct (2).
Follow-up work