Installing the instrument cluster (KOMBI)
- Connect and lock the connector (1) on the instrument cluster (KOMBI) (2).
- Guide in the instrument cluster (KOMBI) (2) in the arrow direction.
- Tighten down screws (1).
TIGHTENING TORQUES SPECIFICATION
| Instrument cluster (KOMBI) to support | ||
| Screw | tightening torque | 1.8 Nm |
- Position and lock the steering column shroud upper section (1).
The snap-in lugs (2) must snap in audibly.
Follow-up work
- Refer to INSTALLING THE DECORATIVE STRIP ON THE RIGHT DASHBOARD .
- Refer to INSTALLING THE SIDE PANEL ON DASHBOARD ON THE RIGHT .
- Refer to INSTALLING THE DECORATIVE STRIP ON THE DASHBOARD ON THE LEFT .
- Refer to INSTALLING THE SIDE PANEL ON LEFT DASHBOARD .
- Refer to INSTALLING THE INSTRUMENT CLUSTER TRIM .
- Refer to ACTIVATING VEHICLE-SPECIFIC HIGH-VOLTAGE OR LOW-VOLTAGE ELECTRICAL SYSTEM .