LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> X5 xDrive45e >> Repair and Diagnosis >> External Pages >> Different car >> Section 269 (Oxygen Sensors - Repair (G07)) >> 11 78 Oxygen Sensors >> 11 78 530 Replacing left front oxygen sensor (after vehicle diagnosis) (X7 M50i 2020-2022) >> Installing the left Lambda oxygen sensor

Installing the left Lambda oxygen sensor

WARNING: This page is about a different car, the 2022 BMW X7, 2021 BMW X7, 2020 BMW X7, and 2019 BMW X7. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Hot surfaces  .
Risk of burning! 
  • Perform all work only on components that have cooled down.
NOTE: RISK OF DAMAGE 
Electrostatic discharge  .
Damage to or destruction of electrical components  .
  • Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
  • Read and comply with user information on using the associated special tool 12 7 060.
  • Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
  • Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
  • For additional information see: 61 35... NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION
TIGHTENING TORQUES SPECIFICATION

Carrier plate to the cylinder head covers
M6x12 screw tightening torque  10 Nm
G14386135Courtesy of BMW OF NORTH AMERICA, INC.

Follow-up work