LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> X5 xDrive45e >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Technical Data -- X5 (G05) >> 17 00 Cooling, Test >> 17 00 COOLING, TEST (X5 xDrive 50i, X5 M50i 2019-)

17 00 COOLING, TEST (X5 xDrive 50i, X5 M50i 2019-)

17 00 TECHNICAL DATA OVERVIEW

Coolant level 
  Overfill quantity of coolant (above the maximum mark) In the high-temperature expansion tank  + 200 ml
  Overfill quantity of coolant (above the maximum mark) In the low-temperature expansion tank (If Installed)  + 100 ml
Cooling system test pressure 
  Test pressure for cooling system (gauge pressure)  1.5 bar
Filling capacity of high-temperature coolant circuit G05/G06 N63B144M3 N63B44T3 
  N63B44M3/N63B44T3  12.6 l
  N63B44M3/N63B44T3 (SA823)  13.6 l
Low-temperature coolant circuit filling capacity G05/G07 
  N63B44M3/N63B44T3  5.4 l
Opening pressure of coolant seal cover 
  Pressure relief valve opens when the pressure exceeds the ambient pressure.  min. 2.0 bar
  Electric changeover valve must open at latest when the pressure is lower than the ambient pressure  max. 0.1 bar
Test conditions for coolant level 
  Coolant must be cooled down