LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> X5 xDrive45e >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Engine - Turbocharger/EGR/O2 Sensor - Repair - X5 (G05) >> 11 78 Co Adjustment, Oxygen Sensor >> 11 78 533 Replacing right front oxygen sensor (after vehicle diagnosis) (X5 M50i, 2020-) >> Installing the right Lambda oxygen sensor

Installing the right Lambda oxygen sensor

WARNING: Hot surfaces  .
Risk of burning! 
  • Perform all work only on components that have cooled down.
NOTE: RISK OF DAMAGE 
Electrostatic discharge  .
Damage to or destruction of electrical components  .
  • Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
  • Read and comply with user information on using the associated special tool 12 7 060.
  • Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
  • Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
  • For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
TIGHTENING TORQUE SPECIFICATIONS

Front Lambda oxygen sensor/oxygen sensor monitor on catalytic converter
M18x1.5 tightening torque  50 Nm
G14386142Courtesy of BMW OF NORTH AMERICA, INC.
G14386140Courtesy of BMW OF NORTH AMERICA, INC.

Follow-up work