Remove air supply system
CAUTION:
Residual pressure in the air supply system
.
Injury hazard!
Injury hazard!
- After the air spring system is emptied using the diagnostic system, there is still a certain amount of residual pressure in the system. It is mandatory to follow the handling instructions.
- Carefully slacken the banjo bolts (1) and (2) on the air lines on the valve block of the air supply system until you can hear air leaking (hissing noise).
- Wait approx. 2 min until the pressure in the air spring system is completely relieved.
The hissing noise stops.
- Fully release the banjo bolts (1) and (2) after having completely reduced the pressure.
- Unlock plug connection (3) and disconnect.NOTE: TECHNICAL INFORMATION
Secure component against falling. - Loosen nuts (1).
- Remove the air supply system (2).