Connect the coolant line of low-temperature coolant circuit
NOTE:
TECHNICAL INFORMATION
Make sure that the connections are locked correctly. The locks must engage audibly.
Make sure that the connections are locked correctly. The locks must engage audibly.
- Check the sealing ring (1) of the coolant line (2) for damage and replace if necessary.
- Connect and lock coolant line (1).
- Make sure that the coolant line (1) engages audibly.
Follow-up work
- Refer to INSTALLING THE CLEAN AIR PIPE AND THE RESONATOR .
- Refer to INSTALLING FRONT UNDERBODY PROTECTION .
- Refer to INSTALLING THE INTAKE FILTER HOUSING (TENSION STRUT REMOVED ON SHOCK TOWER) .
- Refer to INSTALLING THE TENSION STRUT ON THE RIGHT SHOCK TOWER .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to FILLING THE LOW-TEMPERATURE COOLING SYSTEM WITH THE VACUUM FILLING EQUIPMENT .
- Refer to VENTING THE LOW-TEMPERATURE COOLING SYSTEM .