Home >> BMW >> 2021 >> X5 xDrive40i >> Repair and Diagnosis >> Body & Frame >> Seats >> Seats - Repair -- X5 (G05) >> 52 26 Rear Seat, Through-Loading >> 52 26 008 Removing and installing/replacing backrest side section on left or right rear seat backrest (all X5 models, 2019-2022) >> Remove armrest side section

Remove armrest side section

NOTE: Description is for left component only. Procedure on the right side is identical.

Removing the backrest side section without side airbag 

G14383102Courtesy of BMW OF NORTH AMERICA, INC.

Deactivating the 48 V electrical system 

Prerequisite 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system  .
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
WARNING: Deactivate the 48-V electrical system  .
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
NOTE: RISK OF DAMAGE 
Damage to the 48-V battery 
If a 48-V battery that is disconnected from the electrical system is activated, the battery electronics will be damaged  .
  • Only ever activate the 48 V electrical system when the 48 V battery is fully connected up.
NOTE: TECHNICAL INFORMATION 
Observe notes on the 48-V battery. See additional information NOTES ON THE 48-V BATTERY .
G14192777Courtesy of BMW OF NORTH AMERICA, INC.

Check 

NOTE: TECHNICAL INFORMATION 
Zero voltage (48 V electrical system switched-off) is only displayed in PAD mode.
G14192778Courtesy of BMW OF NORTH AMERICA, INC.

Desired state 

Result 

» Absence of voltage  cannot be specified with the Check Control message "48 V electrical system switched off." (1). Work start is not permitted.

Measure

Result 

» The Check Control message reports that 48 V electrical system is switched off.

Measure

"Disconnect the negative battery cable of the 48-V battery" work can be started.

G14192780Courtesy of BMW OF NORTH AMERICA, INC.
WARNING: Unprotected battery terminals  .
Risk of short circuits! Risk of fire! 
  • Cover the vehicle battery.
G14192781Courtesy of BMW OF NORTH AMERICA, INC.

Disconnecting all battery ground leads 

G13797979Courtesy of BMW OF NORTH AMERICA, INC.

Removing the backrest side section with side airbag 

WARNING: Airbag unit  .
Danger! Immobilization period-threatening injuries! 
WARNING: Pyrotechnic components  .
Danger! Immobilization period-threatening injuries! 
G14383110Courtesy of BMW OF NORTH AMERICA, INC.