LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> X5 sDrive40i >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Engine - Coolant Thermostat & Lines/Intake System/Turbocharger - Repair - X5 (G05) >> 11 65 Charger With Control >> 11 65 020 Removing and installing/replacing exhaust turbocharger (X5 xDrive 40i, 2019-, X5 sDrive 40i, 2020-) >> Installing exhaust turbocharger

Installing exhaust turbocharger

NOTE: RISK OF DAMAGE 
Damage of the electric wastegate valve controller  .
Excessive force when removing and installing a jammed exhaust turbocharger may damage the electric wastegate valve controller  .
  • Do not pull on the electric wastegate valve controller.
  • Apply force only at the turbine housing and exhaust manifold.
  • Do not pull on the compressor housing.
G14238443Courtesy of BMW OF NORTH AMERICA, INC.

Follow-up work