Securing the wiring harness section from the cylinder head cover on the left
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
NOTE:
RISK OF DAMAGE
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
- Do not pull on wires when disconnecting connectors and plug connections.
- Position wiring harness section (4).
- Position the grounding point (2).
- Tighten the screws (1).TIGHTENING TORQUE SPECIFICATIONS
Cable duct to cylinder head cover/cylinder head M6 screw tightening torque
10 Nm - Connect the plug connections (3) and lock.
- Secure the wiring harness mounting (2).
- Tighten the screws (1).TIGHTENING TORQUE SPECIFICATIONS
Cable duct to cylinder head cover/cylinder head M6 screw tightening torque
10 Nm - Carefully pull the coolant hose (2) upwards over the refrigerant line (3) in the marked area and set aside.
- Lock the holder (1).
- Position wiring harness section (4).
- Position the grounding point (3).
- Tighten down screw (2).TIGHTENING TORQUE SPECIFICATIONS
Ground cable to cylinder head cover/cylinder head M6 tightening torque
10 Nm - Fix the wiring harness mounting in areas (1).
- Secure the wiring harness mounting (3).
- Fix wiring harness section (1) in area (2).
- Fix the wiring harness mounting in areas (1).
- Connect connectors (2) and lock.