Releasing the positive battery cables partially
NOTE:
RISK OF DAMAGE
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
- Do not pull on wires when disconnecting connectors and plug connections.
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE)
- Loosen screw (1) .
- Release the wiring harness mountings (2) .
- Place the wiring harness (3)
on the side.NOTE: To provide a better overview: Illustration of surrounding parts removed.
- Loosen screw (1) .
- Release nut (3) .
- Lay the grounding point (5) to one side.
- Loosen screw (4) .
- Release the clip (2) .