Releasing the positive battery cables
NOTE:
RISK OF DAMAGE
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
- Do not pull on wires when disconnecting connectors and plug connections.
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
- Unlock lock (1).
- Guide the cover (2) out in the arrow direction and remove it.
- Loosen nut (1).
- Pull the positive battery cable (2) out and set it aside.
- Feed out and remove the cover (1).
- Release nuts (1).
- Feed out positive battery cables (2) and place to one side.