6452... Instructions for opening and part exchange in refrigerant circuit
Special tools required:
- 00 9 030
- 32 1 270
WARNING:
- Avoid contact with refrigerant and refrigerant oil
- Follow Safety instructions for HANDLING R 134A REFRIGERANT
- Follow safety instructions for HANDLING REFRIGERANT OIL
Attention!
- Always use new O-rings each time A/C connections are opened (obtainable via BMW)
They must not be coated.
Use special tool 00 9 030 to install sealing rings without damaging them.
- Open the refrigerant circuit for as short of a period as possible.
- Close all components and lines in the refrigerant circuit and return parts immediately following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
- If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 h, the dryer insert for the air conditioning must be replaced.
I. Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage.
(minor leak, e.g. hairline crack)
Procedure:
- Suction the AIR CONDITIONING SYSTEM , then determine suctioned coolant oil level
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 10 ml
- Air conditioning condenser: 20 ml
- Desiccant insert/dryer flask: 20 ml
- Each replaced refrigerant line: 10 ml
- Air conditioning condenser with integrated dryer flask: 40 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- Evacuate and fill the AIR CONDITIONING SYSTEM
II. Part replacement due to sudden leakage
(major leak, e.g. pipe break due to accident)
Procedure:
- Suction HEATING AND AIR CONDITIONING SYSTEM , then determine suctioned coolant oil level
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 35 ml
- Air conditioning condenser: 35 ml
- Desiccant insert/dryer flask: 55 ml
- Each replaced refrigerant line: 35 ml
- Air conditioning condenser with integrated dryer flask: 55 ml
- Safety pressure switch and gasket: no additional refrigerant oil