54 13... Notes on panorama glass roof (initialization/normalization/learning of characteristic curve)
Initialization comprises:
- Initialization of the glass slide/tilt sunroof panel
- Initialization of the roller sunblind
Then carry out initialization:
- if the panorama glass roof has been mechanically moved by means of the emergency actuator
- In the event of malfunctions, e.g. no one-touch function, no opening or no comfort function possible
- after disengagement of the drive unit
- after repair work is carried out on the mechanism of the panorama glass roof
- after exchange of the control unit
- After removal and installation or adjustment of a glass slide/tilt sunroof panel
- After removal and installation of the complete panorama glass roof
WARNING:
There is no anti-trap mechanism during initialization.
Ensure adequate voltage supply during initialization.
If necessary, recharge battery.
Ensure adequate voltage supply during initialization.
If necessary, recharge battery.
The initialization is carried out through the switch of the panorama glass roof.
The switch must be operated in the "vent position" direction during the entire process.
Panorama glass roof can be initialized in any position.
Initialization:
- Switch on ignition.
- Press and hold the switch in the "vent position" direction
- Initialization occurs after approx. 15 seconds
- first the panorama glass roof closes depending on the position
- Panorama glass roof opens and closes once completely
- Initialization of the panorama glass roof is completed the roller sunblind closes next
- Roller sunblind opens and closes once completely
- Initialization of the roller sunblind is completed
- release switch when the roller sunblind is closed
NOTE:
- The entire process takes approx. 60 seconds
- If the switch is released in the meantime, the entire procedure must be repeated
- Carry out function check (one-touch function, anti-trapping protection and, if necessary, comfort function)