Install the Headunit High (HU-H)
- Connect and lock the connector (3) to the head unit (4).
- Correctly position the cable clip (2) and engage it with the detent (1).NOTE: RISK OF DAMAGE
Damage to the instrument cluster (KOMBI) or the head unit
A ground offset can occur when releasing and connecting the cables. This can generate currents that render the instrument cluster (KOMBI) or the head unit unusable.- When releasing: First release the APIX data cable (blue).
- When connecting: Connect the APIX data cable (blue) last.
- Connect and lock all the connectors in the marked area with head unit (1) in the correct assembly sequence.
All cables must be routed correctly.
- Push the head unit (2) into the dashboard and tighten the screws (1).
TIGHTENING TORQUES SPECIFICATION
| Head unit to dashboard | ||
|---|---|---|
| screw | Tightening torque | 1.8 Nm |
Follow-up work