Home >> BMW >> 2021 >> M5 Base >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Electric Converters and Controllers >> General Electrical System -- Repair M5 (F90) >> 61 20 Battery >> 61 20 900 Disconnecting and connecting battery ground lead (M5 2018-2022) >> Disconnecting the negative battery cable of the system battery

Disconnecting the negative battery cable of the system battery

Preliminary work 

Precondition 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system  .
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
NOTE: TECHNICAL INFORMATION 
Follow notes on lithium-ion battery. See NOTES REGARDING THE LITHIUM-ION BATTERY 
G15190149Courtesy of BMW OF NORTH AMERICA, INC.