Installing the operating facility in the center console
- Position the operating facility in the (2) center console (3) and connect and lock the associated connector.
- Tighten down screws (1).
tightening torque specification
| Gws to center console trim | ||
|---|---|---|
| Screw | Tightening torque | 1.8 nm |
disconnecting all battery ground leads
- See 61 20 BATTERY GROUND .
activating the 48Velectrical system
Precondition
Ignition is switched off.
NOTE:
Risk of damage
Damage to the 48V battery
If a 48V battery that is disconnected from the electrical system is activated, the battery electronics will be damaged.
Damage to the 48V battery
If a 48V battery that is disconnected from the electrical system is activated, the battery electronics will be damaged.
- Only ever activate the 48Velectrical system when the 48V battery is fully connected up.
- Raise the battery ground cable (1).
- Remove special tool 2 452 007
.
- Release the negative battery cable (2) of the 48V battery from the attachment.
- Position the negative battery cable (2) of the 48V battery on the negative battery terminal.
- Tighten the nut (1).
tightening torque specification
| Negative battery cable to 48V battery | ||
|---|---|---|
| Nut M8 | Tightening torque | 19 nm |
- Connect the connector (1) of the can bus and lock it.
- Clip in the clip (2).
- Activate the 48Velectrical system by closing the hood.
The activation takes place automatically.
Follow-up work
- Refer to INSTALLING THE CENTER CONSOLE TRIM .
- Refer to INSTALLING TRIM IN STORAGE COMPARTMENT OF CENTER ARMREST .
- Refer to CONNECTING ALL BATTERY GROUND LEADS .
- Refer to ACTIVATING THE 48V ELECTRICAL SYSTEM .