(Removing the integrated supply module (PDM) partially)
Precondition
Engine control unit has been removed
NOTE:
RISK OF DAMAGE
Electrostatic discharge
Damage to or destruction of electrical components
Electrostatic discharge
Damage to or destruction of electrical components
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away
- Read and comply with user information on using the associated special tool 12 7 060
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol)
- For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
- Release the locks (1)
- Slide out and remove the integrated power supply module (PDM) (2) in the direction of the arrow