Home >> BMW >> 2021 >> M240i 2D Convertible, Automatic Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning -- Repair (F22 & F23) >> 64 50 Refrigerant >> Safety instructions for handling refrigerant oil (2' Series coupe and convertible, 2017-2021)

Safety instructions for handling refrigerant oil (2' Series coupe and convertible, 2017-2021)

WARNING: Injury hazard!
Refrigerant circuit is under high pressure! Work on the refrigerant circuit may only be carried out by experts! 
Draw off refrigerant without fail BEFORE  all repair work on the refrigerant circuit.
The refrigerant circuit is depressurized AFTER suction!
  • Before conducting repairs, check the actual pressure drop on the pressure gauge of the A/C service station

Read and comply with the relevant operating instructions for the A/C service station used!

Protective measures/rules of conduct: 

First aid measures: 

IMPORTANT: Refrigerant is hygroscopic and must therefore be stored in suitable containers that are sealed airtight!
refrigerant oil is non-flammable and nonexplosive at normal temperatures. Nevertheless, the following points must be observed:
  • Do not store in the vicinity of flames, heat sources or strongly oxidizing materials
  • Suitable extinguishing agents are carbon dioxide (CO) dry extinguishing agent and foam

Recycling 

Catch and dispose of emerging refrigerant oil.

Observe country-specific waste disposal regulations.

Absorb leakage refrigerant oil with fluid binding material.

Notify the relevant authorities if larger amounts of refrigerant are discharged into aboveground water supplies, drainage systems or subsoil.