Disconnect the refrigerant line from the expansion valve
CAUTION:
Residual pressure in the heating and air conditioning system.
Injury hazard!
Injury hazard!
- Wear safety goggles and protective gloves when disconnecting the refrigerant line.
- Close the refrigerant lines with seal plugs.
- Open the holder (1).
- Release the nut (1).
- Disengage the hose support (2).
- Remove the refrigerant line (3) and set it aside.