LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> 840i 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 224 (Heating And Air Conditioning -- Repair (G02)) >> 64 50 Refrigerant >> 64 50 010 Extract, evacuate and fill air conditioning system >> Filling the air conditioning

Filling the air conditioning

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2025 BMW X4, 2024 BMW X4, 2023 BMW X4, 2022 BMW X4, and 2021 BMW X4. However, it is still accessible from the selected car via links, so may be relevant.

Precondition 

The engine is switched off.

Heating and air conditioning system is switched off.

The refrigerant circuit is evacuated and tight.

Vehicle must be positioned on the ground.

CAUTION: Refrigerant circuit under high pressure. 
Injury hazard! 
NOTE: TECHNICAL INFORMATION 
Filling a raised vehicle will result in insufficient filling levels.
NOTE: TECHNICAL INFORMATION 
In some cases, Sanden SP-A2 refrigerant oil must be injected into the refrigerant circuit. .


Precondition 

The service function must be active.

The engine is switched off.

Heating and air conditioning system is switched off.

The refrigerant circuit is evacuated and tight.

Vehicle must be positioned on the ground.

CAUTION: Refrigerant circuit under high pressure. 
Injury hazard! 
NOTE: TECHNICAL INFORMATION 
Filling a raised vehicle will result in insufficient filling levels.
NOTE: TECHNICAL INFORMATION 
In some cases, Sanden SP-A2 refrigerant oil must be injected into the refrigerant circuit. .

Check 

TABLE 1  indicates the permitted loss of refrigerant after a specific period of time.

There are no  leaks.

REFRIGERANT OIL SPECIFICATION

Table 1          
Number of years since system last filled 0-1 1-2 2-3 3-4 4-5
Permissible loss [g] ≤ 30 ≤ 60 ≤ 90 ≤ 120 ≤ 150

Result 

» The refrigerant loss is not exceeded in accordance with Table 1.

Measure

Do not  top up refrigerant oil.

Result 

» The refrigerant loss is exceeded in accordance with Table 1.

Measure

Top up refrigerant oil according to TABLE 2 .

TABLE 2  indicates the amount of refrigerant oil to be added  after a specific period of time in the case of an unacceptable  loss of refrigerant due to a leak.

REFRIGERANT OIL SPECIFICATION

Number of years since last filling Loss of refrigerant [g] Top up quantity refrigerant oil
0-1 < 120 0
0-1 120-150 10
0-1 > 150 20
1-2 < 180 0
1-2 180-210 10
1-2 > 210 20
2-3 <240 0
2-3 240-270 10
2-3 > 270 20
3-4 < 300 0
3-4 300-330 10
3-4 > 330 20
4-5 < 360 10
4-5 > 360 20

Check 

Result 

» Version A:  Parts of the refrigerant circuit were used as preliminary work for further work or swapped out due to a gradual leakage (minor leak, e.g. hairline crack).

Version B:  Parts of the refrigerant circuit have been replaced due to sudden loss of refrigerant (major leak, e.g. broken pipe due to accident).

Measure

REFRIGERANT OIL SPECIFICATION

  Version A Version B
Air conditioning compressor(1). (1). (1).
Evaporator 10 ml 35 ml
Air conditioning condenser without integrated desiccant insert 20 ml 35 ml
Air conditioning condenser with integrated desiccant insert 40 ml 55 ml
Desiccant insert/dryer flask 20 ml 55 ml
Per replaced refrigerant line 10 ml 35 ml
Safety pressure switch, gaskets 0 ml 0 ml
(1) Air conditioning compressor: see LUBRICATING THE AIR CONDITIONING COMPRESSOR (COOLANT OIL LEVEL IN NEW AIR CONDITIONING COMPRESSOR IS KNOWN) , or LUBRICATING THE AIR CONDITIONING COMPRESSOR (COOLANT OIL LEVEL IN NEW AIR CONDITIONING COMPRESSOR NOT KNOWN) .