Home >> BMW >> 2021 >> 840i 2D Convertible >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel System -- Repair (G14, G15, & G16) >> 13 51 Fuel Injection Pump >> 13 51 017 Removing and installing high pressure pump (840i and 840i xDrive coupe/convertible/Gran Coupe sedan) >> Remove high pressure pump

Remove high pressure pump

WARNING: Working on fuel system  .
Risk of fire! Danger of explosion! 
  • When working on the fuel system, make sure the workstation has sufficient ventilation, e.g., by means of extraction.
  • Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
  • No fire, sparks, open flames or smoking.
WARNING: Working on 12 V electrical system  .
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
  • Detach battery ground lead from battery.
  • For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
CAUTION: On releasing high pressure line, fuel may emerge at high speed  .
Injury hazard! 
  • Wear suitable personal protective equipment.
  • Before performing any installation work, allow cooling system to cool down to less than 40°C.
  • Note warnings on cylinder head cover.
NOTE: RISK OF DAMAGE 
Contaminant or foreign body  .
Contamination can result in malfunctions, loss of function or leaks  .
  • Adhere to the utmost cleanliness.
  • Protect components from contamination e.g. by covering.
  • Close off line connections with seal plugs.
NOTE: TECHNICAL INFORMATION 
When the engine is stopped after the completion of trip, it may be necessary to run the electric fan. In rare cases, operation of the electric fan can last up to 11 min. This protects the components. In this case, replacing the electric fan will not remedy the problem!

Preliminary work 

NOTE: RISK OF DAMAGE 
Contaminant or foreign body  .
Contamination can result in malfunctions, loss of function or leaks  .
  • Adhere to the utmost cleanliness.
  • Protect components from contamination e.g. by covering.
  • Close off line connections with seal plugs.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
NOTE: TECHNICAL INFORMATION 
The high pressure pump is preloaded by the piston spring and must be removed by alternately unscrewing the screws without tilting.
Before installing the high pressure pump, the cam of the high pressure pump drive must be turned to bottom dead center.
If necessary, turn the engine in the direction of engine rotation on the central bolt of the crankshaft, otherwise there is a risk of piston breakage of the high pressure pump.