Installing Lambda oxygen sensor
NOTE:
TECHNICAL INFORMATION
Grease the threads of new oxygen sensors thinly and evenly.
For oxygen sensors that are reused, the following should be observed:
Thinly and evenly grease the oxygen sensor on the thread only. Do not clean the part of the oxygen sensor that does not protrude into the exhaust line (sensor ceramics) and do not grease.
Grease the threads of new oxygen sensors thinly and evenly.
For oxygen sensors that are reused, the following should be observed:
Thinly and evenly grease the oxygen sensor on the thread only. Do not clean the part of the oxygen sensor that does not protrude into the exhaust line (sensor ceramics) and do not grease.
- Prepare the oxygen sensor.
The sensor ceramics must not be damaged.
(1) = Thread
(2) = Sensor ceramics
- Lightly and evenly grease the thread (1) of the oxygen sensor monitor.CONSUMABLE SPECIFICATIONS
Brake block paste
* TU = Trade Unit. TU numbers cannot be ordered! For invoicing purposes only.3 g, Bag 83192158851 100 g, Tube 83192158852 5 g, TU* 83230140233
NOTE:
The cable of the Lambda oxygen sensor is black. The installation location of the Lambda oxygen sensor is in front of the catalytic converter.
- Screw in the Lambda oxygen sensor (1) and tighten with the special tool 0 491 074 (11 7 020) .
TIGHTENING TORQUE SPECIFICATIONS
| Lambda oxygen sensor on catalytic converter | ||
|---|---|---|
| M18X1.5 | tightening torque | 50 Nm |
- Feed in heat shield (4) in the arrow direction and install.
- Replace the cable ties (3).
Parts: Cable tie
- Guide in cable tie (3) and install.
- Guide the line of the Lambda oxygen sensor (1) into the bracket (2) and install.
- Feed in and install the connector (1) in the arrow direction .
- Make sure that the lock (2) snaps-in audibly.
- Connect and lock the connector (1).
- Make sure the connector (1) engages audibly.
Follow-up work
- Refer to INSTALLING THE RESONATOR WITH THE TOP CLEAN AIR PIPE .
- Refer to INSTALLING INTAKE SILENCER HOUSING .
- Refer to INSTALLING ACOUSTIC COVER .