Installing the integrated power supply module
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
NOTE:
TECHNICAL INFORMATION
Follow instructions for removing and installing control units.
For additional information see: INSTRUCTIONS FOR REMOVAL AND REPLACEMENT OF CONTROL UNITS .
Follow instructions for removing and installing control units.
For additional information see: INSTRUCTIONS FOR REMOVAL AND REPLACEMENT OF CONTROL UNITS .
NOTE:
TECHNICAL INFORMATION
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
- Position the integrated power supply module.
- The clamps (3) of the control unit bracket (4) must engage audibly.
- Connect connectors (2) and lock.
- Connect connectors (1) and lock.
Follow-up work
- Refer to INSTALLING THE COVER OF THE RIGHT DME CONTROL UNIT .
- Refer to CONNECTING ALL BATTERY GROUND LEADS .