Adjusting Night Vision camera
- Connect diagnostic system. Select following service functions.
- Assistance system
- Night Vision Electronics
- Calibration of night vision electronics camera
- Front of vehicle must be parallel at distance (A) to headlight aiming device (1). (A) = 2 m.
- Align a suitable straight object (2), e.g. a spirit level, horizontally on headlight aiming device.
- Adjust Night Vision camera using diagnostic system.
- Yellow guide line (1) is displayed with the diagnostics job.
- Upper edge (2) must be aligned using diagnostic system parallel to yellow help line (1) in the CID.