Replacing the seal on rear door
- Pull the seal (1) off of the door, beginning in the area (A).
- Remove the seal plug (1).NOTE: TECHNICAL INFORMATION
The repair notes of bonded seals form the basis for these repair instructions and must be observed without fail.
For additional information see: REPAIR NOTES FOR BONDED SEALS .NOTE: Schematic diagram is for example purposes. Some parts may differ in certain details. - Clean the bonding surface on the inner door panel with adhesive remover (sourcing reference: BMW Group parts sales).
- If necessary, detach the pre-cut cutouts (2) for the screws and openings from the template (1).
- Before adhering, align template (1) on the inner door panel (2).
The edge of the template (1) must run parallel to the bending radius of the inner door panel (2).
The markings and cutouts (3) of the template (1) must match with the corresponding bore hole of the inner door panel (2).
- Replace the seal on the rear door.
Parts: Seal on the rear door
- Guide in the seal (1) below the window channel strip (2) and position on the template (3).
- Position seal (1) along the template (3).
The seal (1) must be on the mark (4) (arrow) of the template (3).
- Bond the seal
(1) as follows:
Detach protective film (2) step by step.
Correspondingly, align seal (1) on template (3) and gently press it on.
Check the position of the seal (1) and correct if necessary.
Position seal (1) without stretching or compressing it.
Always apply pressure perpendicular to the bonding surface to affix the seal (1).
Affix seal (1) with firm thumb pressure.
- Bond the seal
(1) as follows:
Gradually detach protective film.
Align seal (1) to match the specified dimension (X) and press on lightly
Check the position of the seal (1) and correct if necessary.
Position seal (1) without stretching or compressing it.
Maximum permissible sag of the seal (1) during the positioning process is 30 mm.
Always apply pressure perpendicular to the bonding surface to affix the seal (1).
Affix seal (1) with firm thumb pressure.
Guide the seal (1) under the door well cover in the area (2).
Area Dimension A 16.6 mm B 18.6 mm C 9.5 mm - Install seal plug (1).