Removing front lower strap
NOTE:
TECHNICAL INFORMATION
Clean all threaded belt connections with micro-encapsulated outer and internal threads.
Shavings or other debris must not remain in the components.
If a microencapsulated screw is reused, it must be coated with the following screw locking agent: Loctite 243, medium strength .
The screw connection must be completed within 10 minutes as hardening begins after this period.
Clean all threaded belt connections with micro-encapsulated outer and internal threads.
Shavings or other debris must not remain in the components.
If a microencapsulated screw is reused, it must be coated with the following screw locking agent: Loctite 243, medium strength .
The screw connection must be completed within 10 minutes as hardening begins after this period.
NOTE:
Description is for left component only. Procedure on the right side is identical.
Preliminary work
- Refer to REMOVING FRONT SEAT .
- Loosen screw (1).
- Disconnect the connector (2) and unclip the present cable holder.
- Pull out the lower belt (3) and remove.