Install the wiring harness section for the Valvetronic servomotor
NOTE:
RISK OF DAMAGE
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
- Route all cables without abrasions, do not trap and crush.
- Guide in the wiring harness section (3) and install.
- Connect connectors (2) and lock.
The connector (2) must engage audibly.
- Feed in and install the tank ventilation line (1).
- Guide in the wiring harness section (1) and install.
- Fasten the wiring harness mounting (arrows).
- Connect connectors (1) and lock.
The connectors (1) must engage audibly.
Follow-up work
- Refer to INSTALLING THE COVER OF THE DME CONTROL UNIT .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to RECONNECTING ALL BATTERY GROUND LEADS .
- Refer to ACTIVATING THE 48 V ELECTRICAL SYSTEM .