Install the wiring harness section for the ignition and injectors
NOTE:
RISK OF DAMAGE
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
- Route all cables without abrasions, do not trap and crush.
- Guide in and Install the wiring harness section for the ignition and injectors (4).
- Connect and lock the holder (3).
- Connect and lock the holder (2).
- Secure clamps (1).
The holder (3) and clamps (1) must be heard to engage.
- Connect connectors (1) to injectors and lock.
The connectors (1) must engage audibly.
- Connect the connectors to the injectors.
- Lock the locking mechanism (1) the arrow direction.
The lock (1) must audibly engage.
- Thread in cable duct (3) and install.
- Feed in ground cable (2) and install.
- Tighten nut (1).
TIGHTENING TORQUE SPECIFICATION
| Ground cable to rail | ||
|---|---|---|
| M6 | tightening torque | 5 Nm |
- Connect and lock connectors (arrows).
The connectors (arrows) must audibly engage.
- Connect connectors (1) and lock.
The connectors (1) must engage audibly.
Follow-up work
- Refer to INSTALLING THE COVER OF THE DME CONTROL UNIT .
- Refer to INSTALLING ACOUSTIC COVER AT REAR .
- Refer to INSTALLING THE REAR HOOD SEAL .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to RECONNECTING ALL BATTERY GROUND LEADS .