Installing the safety battery terminal
- Position the safety battery terminal (3) on the positive battery terminal.
- Close the holder (1).
- Tighten nut (2).
tightening torque specification
| Positive battery terminal to battery | ||
|---|---|---|
| Nut | Tightening torque | 5 nm |
- Position the positive battery cable (2) on the safety battery terminal.
- Tighten nut (1).
tightening torque specification
| Positive battery cable to safety battery terminal | ||
|---|---|---|
| Flange Nut M8 | Tightening torque | 15 nm |
- Close the positive terminal cover (1).
- Position the positive battery cable (2) on the power distribution.
- Tighten nut (1).
tightening torque specification
| Positive battery cable to power distribution box | ||
|---|---|---|
| Flange Nut M8 | Tightening torque | 15 nm |
- Position the cover (1) and clip it in at the marked areas.
- Position cable (2).
- Clip in the holder (1).
- Position the cable (3) and clip in the bracket (1).
- Connect connectors (2) and lock.
Check
- Check guides (1) and the detent (3) on the protective cap (2) for damage.
Result
» guides (1) or detents (3) are damaged.
Measure
- Replace protective cap (2).
- Clip in the guides (3) of the protective cap (1) into the associated openings on the positive battery terminal in arrow direction.
- Clip in the protective cap (1) with the detent (2).
Follow-up work
- Refer to CONNECTING ALL BATTERY GROUND LEADS .