Home >> BMW >> 2021 >> 430i 2D Convertible >> Repair and Diagnosis >> Body & Frame >> Exterior/Interior Trim >> Body Equipment -- Repair (G22, G23 & G26) (2 Of 3) >> 51 31 Windshield And Rear Window >> 51 31 011 Replace windshield (4' Series convertible models) >> Installing the rain-light-solar-condensation sensor

Installing the rain-light-solar-condensation sensor

Check 

NOTE: RISK OF DAMAGE 
Damage to silicone surface  .
A damaged silicone surface can lead to malfunctioning of the rain-light-solar-condensation sensor  .
  • Do not tap or damage the siliconecoated surface on the rain-light-solar-condensation sensor.
  • After loosening lock, wait approx. 30 min. at 20°C for silicone surface to relax.
G14906793Courtesy of BMW OF NORTH AMERICA, INC.

Result 

» Sensor (2)  is damaged.

Measure 

Result 

» Silicone surface is damaged (1)  .

Measure 

Replacing the gel pad for rain-light-solar-condensation sensors

Result 

» Silicone surface (1)  and sensor (2)  do not show signs of damage.

Measure 

G14645653Courtesy of BMW OF NORTH AMERICA, INC.

Check 

G09928953Courtesy of BMW OF NORTH AMERICA, INC.

Result 

» Contact surface exhibits air pockets.

Measure 

G14645649Courtesy of BMW OF NORTH AMERICA, INC.