Home >> BMW >> 2021 >> 330e >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Battery Management Systems >> General Electrical System -- Repair (G20) (1 Of 2) >> 61 20 Battery >> 61 20 900 Disconnecting and connecting battery ground lead (330e PHEV and 330e xDrive PHEV) >> Disconnecting the negative battery cable of the system battery

Disconnecting the negative battery cable of the system battery

Prerequisite 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system  .
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
NOTE: RISK OF DAMAGE 
Damage to battery terminal, the safety battery terminal or the intelligent battery sensor (IBS)  .
Damaged battery terminals can lead to malfunctions or vehicle electrical system faults  .
  • Detach battery terminal from battery pole by carefully shifting to and fro. Do not pry off using a tool.
G14644966Courtesy of BMW OF NORTH AMERICA, INC.