Removing the clean air pipe with the resonator
WARNING:
High-voltage system
.
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
- All work on the high-voltage system may only be carried out by specially trained and technically experienced personnel.
- For additional information see:
- For additional information see:
Preliminary work
- Refer to REMOVING THE ACOUSTIC COVER .
WARNING:
Hot surfaces.
Risk of burning!
Risk of burning!
- Perform all work only on components that have cooled down.
- Unlock the locks (1).
- Feed the engine ventilation line (2)
out and set it aside.
- Unlock plug connection (1) and disconnect.
- Loosen clamp (2).
- Unfasten clamp (3).
- Disconnect the clean air pipe with resonator from the intake filter housing.
- Press and hold the clean air pipe with the resonator (1) in arrow direction.
- Version A:
- Unlock and disconnect the tank ventilation line (1).
- Loosen the clamp (arrow).
- Unlock plug connection (1) and disconnect.
- Unlock the clamp (2).
- Feed the clean air pipe out with the resonator (3) and remove it.
- Version B:
- Unlock plug connection (1) and disconnect.
- Loosen clamp (2).
- Unlock and detach the line (2).
- Unlock the clamp (1) and snap it in this position.
- Unlock the clean air pipe with the resonator (1) and detach it.
- Feed the clean air pipe out with the resonator (1) and remove it.