Install the coolant expansion tank for the low-temperature coolant circuit
CAUTION:
Materials harmful to health.
Contact with fluids harmful to health!
Contact with fluids harmful to health!
- Note and follow safety instructions on containers.
- Conduct all work in appropriate personal protective equipment only.
NOTE:
TECHNICAL INFORMATION
Immobilization period-long fill of coolant!
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
Immobilization period-long fill of coolant!
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
NOTE:
TECHNICAL INFORMATION
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
- Guide the coolant expansion tank (1) in and connect the coolant hose below the coolant expansion tank.
- Secure the coolant hose with the spring strap clamp (2).
- If fitted: Connect coolant hose (2) to the coolant expansion tank (1) and audibly lock it.
- Connect coolant hose (3) to the coolant expansion tank (1) and audibly lock it.
- Mount the coolant expansion tank for the low-temperature cooling circuit on the holder.
- Tighten down screws (1).
TIGHTENING TORQUE SPECIFICATIONS
| Coolant expansion tank for the low-temperature coolant circuit to holder | ||
|---|---|---|
| M6 | Tightening torque | 10 Nm |