Installing the rain-light-solar-condensation sensor
Check
NOTE:
RISK OF DAMAGE
Damage to silicone surface .
A damaged silicone surface can lead to malfunctioning of the rain-light-solar condensation sensor .
Damage to silicone surface .
A damaged silicone surface can lead to malfunctioning of the rain-light-solar condensation sensor .
- Do not tap or damage the silicone coated surface on the rain-light-solar condensation sensor.
- After loosening lock, wait approx. 30 min. at 20°C for silicone surface to relax.
- Check silicone surface (1) for damage.
Result
» Silicone surface is damaged (1) .
Measure
- Replace rain-light-solar-condensation sensor.
- Carefully clean windshield in contact area (1)
of rain-light-solar-condensation sensor.
- Guide in the rain-light-solar-condensation sensor (2) in the holder and press on the center of the retaining springs (1) .
- To lock it in place, press down the retaining springs (1) on each side one after the other.
Check
- Check contact surface externally for air pockets.
Visible shades (1) are not air pockets, rather the optical element of the rain-light-solar-condensation sensor (2) . The shades (1) do not represent a functional limitation.
Result
» Contact surface exhibits air pockets.
Measure
- Remove rain-light-solar-condensation sensor and reinstall it.
- Connect connectors (1) and lock.