Install the electrical auxiliary coolant pump for the charge air cooler or the air conditioning condenser
- Feed in and position the electrical auxiliary coolant pump (4) .
- Insert and install the holder (2) .
- Tighten nut (1) .
TIGHTENING TORQUE SPECIFICATION
| Electric coolant pump to holder | ||
| M6 | tightening torque | 8 Nm |
- Connect connectors (3) and lock.
The connector (3) must engage audibly.
NOTE:
TECHNICAL INFORMATION
Make sure that the connections are locked correctly. The locks must engage audibly.
Make sure that the connections are locked correctly. The locks must engage audibly.
- Connect and lock coolant lines (1) and (2) .
The coolant lines (1) and (2) must audibly engage.
Follow-up work
- Refer to FILLING THE LOW-TEMPERATURE COOLING SYSTEM WITH THE VACUUM FILLING EQUIPMENT .
- Refer to VENTING THE LOW-TEMPERATURE COOLING SYSTEM .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to INSTALLING THE STIFFENING PLATE .
- Refer to INSTALLING FRONT UNDERBODY PROTECTION .