Reduction or shutdown of individual electrical consumer
The shutdown of individual consumer units or reduction of the power consumption lowers the power consumption in critical situations. This prevents the battery from discharging. The power management controls the switch-off of individual consumers or reduction in the power consumption using requests (messages) to the relevant control units.
With the engine running
With the engine running, individual functions are divided into two classes:
- Class A: A reduction in the power consumption or a shutdown of these consumers is only perceived by the driver to a limited extent or after a delay.
A shutdown of individual class A consumer units or reduction in the power consumption is only activated under the following 2 conditions:
- Battery charge state in the critical range
- High utilization of capacity of the alternator or reduced utilization of capacity of the alternator due to excess temperature.
- Class B: A reduction in the power consumption or a switch-off of these functions is detected by the driver immediately. Shutdown of individual Class B electrical consumers or reduction of the power consumption is only activated under the following condition:
- Battery charge state in the critical range (close to the startability limit)
In the event of alternator fault
- In the event of an electrical or mechanical fault on the alternator (reduced alternator availability), the power consumption of Class A and Class B electrical consumers is reduced by the allowable maximum amount in order to lower the power demand from the vehicle electrical system.
- If alternator load is reduced due to excessive temperature (protective function), only the power consumption of Class A electrical consumers is reduced by the maximum amount allowable.
In the event of an engine shutdown (MSA)
To prevent excessive power consumption when the engine is switched off (MSA function), power consumption of Class A electrical consumers is reduced by the maximum amount allowable and that of Class B consumers by Reduction no. 1 (see table below).
With the engine off and the ignition switched on
With the engine off and the ignition switched on, consumers are not switched off or their power consumption is not reduced.
Class A electrical consumers
Under the conditions described, the following measures for class A consumers are executed in succession:
| No. | Function | Operation | Control unit (depending on version) |
|---|---|---|---|
| 1 | Heated rear window | Pulsing | IHKA |
| Electronic ride height control | Delayed compressor activation | EHC | |
| 2 | Rear seat heater | Stage 2 | Rear seat modules or JBE |
| Electric auxiliary heater, rear | 75 % | FKA | |
| 3 | Seat heating, front | Stage 2 | Front seat module or JBE |
| Rear seat heater | 50 % | Rear seat modules or JBE | |
| 4 | Electric auxiliary heater, rear | 50 % | FKA |
| Heated windscreen, right | Off | SEC | |
| 5 | Seat heating, front | 50 % | Front seat module or JBE |
| Rear seat heater | Level 1 | Rear seat modules or JBE | |
| Heated windscreen, left | Off | SEC | |
| 6 | Electric auxiliary heater, rear | 25 % | FKA |
| Steering wheel heating | 50 % | SZL | |
| Heated side window, front right | Off | SEC | |
| 7 | Electric auxiliary heater, rear | Off | FKA |
| Mirror heating | Off | JBE or FRM | |
| Washer jet heating | Off | JBE | |
| Heated side window, front left | Off | SEC | |
| 8 | Steering wheel heating | Off | SZL |
| 9 | Seat heating, front | Off | Front seat module or JBE |
| Rear seat heater | Off | Rear seat modules or JBE | |
| 10 | Heated rear window | Off | IHKA |
| Top HiFi system or BMW Individual High End audio system | Max. 30 A power consumption after engine start | AMPT |
Class B electrical consumers
Under the conditions described, the following measures for class B consumers are executed in succession:
| No. | Function | Operation | Control unit (depending on version) |
|---|---|---|---|
| 1 | Top HiFi system or BMW Individual High End audio system | Max. 30 A power consumption | AMPT |
| Heater blower, front and rear | 75 % | IHKA, HKA or FKA | |
| Restriction of use of the electric fan by the air conditioning | 66 % | IHKA (only in combination with engine N74) | |
| 2 | Heater blower, front and rear | 50 % | IHKA, HKA or FKA |
| Restriction of use of the electric fan by the air conditioning | 50 % | IHKA (only in combination with engine N74) | |
| 3 | Heater blower, front and rear | 25 % | IHKA, HKA or FKA |
When the battery charge state moves out of the critical range, the functions become 100 % available again.