Installing the electric coolant pump for the charge air cooler and the air conditioning condenser
NOTE:
TECHNICAL INFORMATION
Make sure that the connections are locked correctly. The locks must engage audibly.
Make sure that the connections are locked correctly. The locks must engage audibly.
- Position the electric coolant pump (2).
- Connect connectors (1) and lock.
The connector (1) must engage audibly.
- Insert and install the retainer (2).
- Make sure the retainer (2) is positioned correctly.
NOTE:
RISK OF DAMAGE
Improper screw length can cause component damage.
The use of screws of improper length can lead to component damage.
Improper screw length can cause component damage.
The use of screws of improper length can lead to component damage.
- Note the correct screw length.
- Install screws that correspond to the original length.
- Tighten the screws (1).
TIGHTENING TORQUES SPECIFICATION
| Electric coolant pump on component carrier | ||
| M6 Replace screws. |
tightening torque | 8 Nm |
- Connect and lock coolant line (2) and (3).
- Make sure that you can hear coolant lines (2) and (3) engage.
- Secure the clamp (1).
- Secure the coolant line (3) to the holder (4).
Follow-up work
- Refer to INSTALLING THE THROTTLE BODY .
- Refer to INSTALLING CHARGE AIR LINE .
- Refer to INSTALLING RESONATOR .
- Refer to FILLING THE LOW-TEMPERATURE COOLING SYSTEM WITH THE VACUUM FILLING EQUIPMENT .
- Refer to CONNECTING NEGATIVE BATTERY CABLE OF THE SYSTEM BATTERY .
- Refer to INSTALLING BATTERY COVER IN TRUNK .
- Refer to CONNECTING THE NEGATIVE BATTERY CABLE (12 V BATTERY) .
- Refer to ACTIVATING HIGH-VOLTAGE SYSTEM .
- Refer to INSTALLING FLAP IN RIGHT LUGGAGE COMPARTMENT TRIM PANEL .
- Refer to VENTING THE LOW-TEMPERATURE COOLING SYSTEM .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to INSTALLING THE CENTER UNDERBODY PROTECTION .
- Refer to INSTALLING THE FRONT UNDERBODY PROTECTION .