2003 3BMXV03.2S54 & 3BMXV04.9S62
WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2002 BMW Z8, 2002 BMW Z3, 2002 BMW X5, 2002 BMW M5, and 2002 BMW M3. However, it is still accessible from the selected car via links, so may be relevant.
- Evaporative System Leak Measurement -
Evaporative system monitoring permits detection of leaks in evaporative system with a diameter of .039" (1 mm) and greater. Using a Diagnostic Module-Tank Leakage (DM-TL) connected to an electrical actuated pump located at atmospheric connection of evaporative canister, a pressure test of evaporative system is performed in following order:
- During reference leak measurement, electrical actuated pump delivers through reference restriction. Engine management system measures pump electrical current consumption. See Figure.
- During leak measurement, electrical actuated pump delivers through charcoal canister into fuel tank system. Pressure in evaporative system may be up to 25 hPa depending on fuel level in tank. Engine management system measures pump electrical current consumption. A comparison of currents of reference leak measurement and leak measurement is a measure for leakage in tank. See Figure.
- During pressure test, purge valve needs to be shut. After test canister purge is resumed, remaining pressure in evaporative system is bled off. See Figure.
- Evaporative System Monitoring Structure - See Figure-Figure .
- Diagnosis Frequency & MIL Illumination - See Figure and Figure-Figure .
- Evaporative Purge System Flow Check -
Purge flow from charcoal canister through purge valve is monitored after fuel system adaptation is completed and lambda controller is at closed loop condition. Diagnosis is started during regular purging:
- Monitoring Cycle Of Evaporative Purge System Flow Check
- Step 1 - For Rich Or Lean Mixture - Flow through purge valve is assumed as soon as lambda controller is compensating for a rich or lean shift. After this procedure, diagnosis is completed and evaporative purge system resumes working normally.
- Step 2 - For A Stoichiometric Mixture -
In this case, lambda controller does not need to compensate for a deviation. Therefore, after finishing regular purging, purge valve is opened and closed abruptly several times. Effect of additional cylinder charge triggers a variation of engine idle speed. A predetermined value is reached if system functions properly and diagnosis procedure is completed. To start diagnosis function (step 2) several conditions have to be satisfied:
- Vehicle speed = 0.
- Engine at idle speed.
- Closed loop of lambda controller.
- Coolant temperature greater than fixed limit.
- Engine idle speed variation is less than a fixed limit.
- Monitoring Cycle Of Evaporative Purge System Flow Check