Removing the oxygen sensor monitor
Oxygen sensor monitor
WARNING:
Hot surfaces.
Risk of burning!
Risk of burning!
- Perform all work only on components that have cooled down.
NOTE:
RISK OF DAMAGE
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
Damage to wires when disconnecting connectors and plug connections.
Sheared wires can cause a short circuit.
- Do not pull on wires when disconnecting connectors and plug connections.
NOTE:
The cable of the oxygen sensor monitor is gray. The installation location of the oxygen sensor monitor is behind the catalytic converter.
- Detach the cable (1)
from the clamps (2)
.
- Unlock plug connection (1)
and disconnect.
- Unlock the plug connection (1)
with the screwdriver (2)
and disconnect it and pull it off from the carrier plate.
- Release the monitoring oxygen sensor (1) with the special tools 0 493 751 (11 9150) and 0 491 075 (11 7 030)
- Remove the oxygen sensor monitor (1)
.