Install the DME control unit of cylinders 5 to 8
- Position the DME control unit (2) .
- Clip in adapter plate at the detents (1)
.
- Fix wiring harness mountings (1)
and (2)
.
- Lock the cable bracket (1)
downwards.
- Connect all connectors (1) and lock.
Follow-up work
- Refer to INSTALLING THE COVER OF THE LEFT DME CONTROL UNIT .
- Refer to CONNECTING ALL BATTERY GROUND LEADS .