Disconnecting the connector from the DME control unit and from the power distribution box (PDM)
Prerequisite
Ignition is switched off.
WARNING:
Working on 12 V electrical system.
Risk of short circuits! Risk of fire!
Risk of short circuits! Risk of fire!
- Make sure that there is no charger connected to the jump start terminal in the engine compartment.
- Detach battery ground lead from battery.
- For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
NOTE:
Disconnecting control units may cause fault code entries and functional limitations. Fault code entries must be read out and deleted if necessary.
- Unlock all connectors (1) from front to back and disconnect them from the DME control unit.
- Unlock all the connectors (2) from the power distribution box (PDM) and disconnect them.
- If necessary, disconnect the wiring harness and set it aside.