Removing integrated supply module (PDM)
WARNING:
High-voltage system.
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
- All work on the high-voltage system may only be carried out by specially trained and technically experienced personnel.
- For additional information see:
- For additional information see:
NOTE:
TECHNICAL INFORMATION
With the ignition off and the high-voltage safety plug disconnected, the Check Control message "High voltage system faulty" is displayed by default.
The message "High-voltage system switched off" (absence of voltage) is only displayed when the ignition is switched on.
With the ignition off and the high-voltage safety plug disconnected, the Check Control message "High voltage system faulty" is displayed by default.
The message "High-voltage system switched off" (absence of voltage) is only displayed when the ignition is switched on.
Preliminary work
- Refer to REMOVING THE FLAP IN THE RIGHT-HAND LUGGAGE COMPARTMENT TRIM PANEL .
- Refer to DE-ENERGIZING THE HIGH-VOLTAGE SYSTEM .
- Refer to CHECKING THAT NO VOLTAGE IS APPLIED .
- Refer to DISCONNECTING THE NEGATIVE BATTERY CABLE .
- Refer to DISCONNECTING THE NEGATIVE BATTERY CABLE OF THE VEHICLE BATTERY .
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: 61 35... NOTES ON ELECTRO STATIC DISCHARGE PROTECTION
- Unclip the cover (1) from the holders in the marked areas towards the top.
- Unlock plug connection (1) and disconnect.
- Unlock plug connection (2) and disconnect.
- Loosen the wiring harness (3) from the holder (4).
- Unlock and release the plug connection (5).
- Unlock and loosen all connectors (1).
- Unlock lock (1).
- Guide out and remove the integrated supply module (PDM) (2).