Replacing the auxiliary coolant pump for stationary/auxiliary heating (X6 M)
Special tools required:
- 13 3 010
WARNING:
Risk of burning!
Repair work on the cooling system may only be carried out when it has cooled down.
Recycling
Coolant emerges when coolant lines are detached. Have a suitable collecting vessel ready.
Catch and dispose of emerging coolant.
Observe country-specific waste disposal regulations.
Necessary preliminary work:
- Remove LEFT FLOOR ASSEMBLY COVER .
NOTE:
Clamp off COOLANT HOSES
.
Disconnect coolant hoses (1) with special tool 13 3 010 and release relevant hose clips.
Release screw (2).
Pull off the auxiliary coolant pump (3) and disconnect the associated plug connection.
Tightening torque 64 12 3AZ .
After installation:
- Vent and fill COOLING SYSTEM WITH VACUUM FILLING UNIT .