67 62 020 Removing and installing/replacing flat motor for rear left or right power window regulator
IMPORTANT:
Before replacement of flat motor, observe NOTES on installation status!
Necessary preliminary work:
- Remove REAR POWER WINDOW REGULATOR
Release screws (1).
Remove flat motor (2) from power window regulator.
IMPORTANT:
Ensure that the flat motor (2) is assembled without tension.
After installation:
An initialization must be carried out in order to activate anti-trap mechanism.