66 31 010 Instructions for ACC adjusting device
WARNING: This page is about a different car, the 2013 BMW X5, 2012 BMW X5, and 2011 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.
Requirements for the measurement area for ACC adjusting device
Dimensions:
- Area behind the mirror of at least 80 cm
- Distance between mirror and vehicle 80 cm +/- 5 cm (Distance between mirror and ACC sensor 100 cm +/- 5 cm)
- Total area of work area 360 cm x 660 cm
Maximum irregularity of floor surface:
- Floor surface - adjusting device ≥ 1 mm
- Floor surface - vehicle ≥ 10 mm
Maximum angle of inclination of floor surface - vehicle:
- Downward incline of floor surface maximum 3°, see illustration (1) in Fig 2.
- Upward incline of floor surface maximum 1°, see illustration (2) in Fig 2.
NOTE:
Setting up the ACC adjusting device (one-off task) comprises the following steps:
- Assembly of adjusting device
- Assembly of rail
- Basic setting of adjusting device on measurement area
Detailed setup and operating instructions are enclosed with every ACC adjusting device.