16 11 130 Checking filler cap pressure relief valve
Special tools required:
Set pressure regulator on special tool 16 1 171 fully in "-" direction.
Connect special tool 16 1 171 via compressed air line (1) to workshop/garage compressed air system (8... 10 bar).
Connect pressure sensor (2) of Diagnosis and Information System with a measuring range of 0...3.5 bar.
Select special tool 16 1 172 or 16 1 173 matching vehicle's filler cap and attach to quick release coupling of special tool 16 1 171 .
Install filler cap on selected special tool (3).
Check testing equipment for leaks!
Select "Measurement" function on Diagnosis and Information System (DIS).
Set measuring range according to pressure sensor to 0-3.5 bar.
Increase pressure by 0.2 bar with pressure regulator on special tool 16 1 171 .
Using special tool 13 3 010 , disconnect delivery line from special tool 16 1 171 to tank filler neck.
Wait 60 secs.
Read off final pressure value and compare with starting pressure value.
Measurement evaluation:
| Pressure drop > 0.012 bar | Testing equipment leaking. Check connection points for leaks. |
Check filler cap pressure relief!
Follow same test procedure as for "Checking testing equipment for leaks".
Increase pressure by 0.3 bar with pressure regulator on special tool 16 1 171 .
Measurement evaluation:
| Pressure drop > 0.012 bar | Filler cap pressure relief valve faulty. Replace filler cap. |