LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2017 >> X3 sDrive28i >> Repair and Diagnosis >> External Pages >> Different car >> Section 370 (Heating And Air Conditioning - Repair) >> Air Conditioning, Leak Detection >> 64 52... Instructions for opening and part replacement in refrigerant circuit

64 52... Instructions for opening and part replacement in refrigerant circuit

WARNING: This page is about a different car, the 2013 BMW X5, 2012 BMW X5, and 2011 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING:

Attention! 

  1. Part replacement as preliminary work fur further repair work and based on gradual leakage. 

    (minor leak, e.g. hairline crack)

    Procedure: 

    • DRAW OFF  heating and air conditioning system, then determine drawn-off amount of refrigerant
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
      • Desiccant insert/dryer flask: 20 ml
      • Each replaced refrigerant line: 10 ml
      • Capacitor with integrated dryer: 40 ml
      • Safety pressure switch and gasket: no additional refrigerant oil
    • EVACUATE AND FILL  A/C system
  2. Part replacement due to sudden leakage 

    (major leak, e.g. pipe break due to accident)

    Procedure: 

    • DRAW OFF  heating and air conditioning system, then determine drawn-off amount of refrigerant
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally replace with new refrigerant oil according to parts replaced:
      • Desiccant insert/dryer flask: 55 ml
      • Each replaced refrigerant line: 35 ml
      • Capacitor with integrated dryer: 55 ml
      • Safety pressure switch and gasket: no additional refrigerant oil
    • Evacuate and fill A/C SYSTEM