61 20 503 Vehicle battery - closed current monitoring

Necessary preliminary work: 

To access the battery ground lead, perform the necessary preliminary work described under 61 20 900 DISCONNECTING AND CONNECTING BATTERY EARTH LEAD .

Do not disconnect the battery ground lead! 

NOTE: If several 12V batteries are installed in the vehicle:
Closed-circuit current check is possible on the vehicle battery only. 

Connect diagnostic system.

Connect the clip-on probe to the battery ground lead of the vehicle battery. The arrow on the clip-on probe must point towards the vehicle battery.

Measure closed-circuit current.