16 11 130 Checking filler cap pressure relief valve
Special tools required:
- 13 3 010
- 16 1 171
- 16 1 172
Set pressure regulator on special tool 16 1 171 fully in "-" direction.
Connect special tool 16 1 171 using compressed air line (1) to workshop compressed air system (8... 10 bar).
Connect pressure sensor (2) from Diagnosis and Information System.
Connect special tool 16 1 172 to quick-release coupling (3).
Install fuel filler cap on special tool 16 1 172.
Check testing equipment for leaks .
Select "Measurement/Pressure" function on Diagnosis and Information System (DIS).
Using pressure regulator on special tool 16 1 171, increase pressure by 0.2 bar.
Using special tool 13 3 010 clamp off feed line from special tool 16 1 171.
Read off and note down pressure.
Wait 60 seconds.
Read off pressure again and compare with starting pressure value.
Measurement evaluation:
| Pressure drop > 0.012 bar |
Test equipment leaking. Check connection points for leaks. |
Check fuel filler cap pressure relief valve!
Select "Measurement/Pressure" function on Diagnosis and Information System (DIS).
Using pressure regulator on special tool 16 1 171, increase pressure by 0.3 bar.
Using special tool 13 3 010 clamp off feed line from special tool 16 1 171.
Read off and note down pressure.
Wait 60 seconds.
Read off pressure value again and compare with starting pressure value.
Measurement evaluation:
| Pressure drop > 0.012 bar |
Filler cap pressure relief valve faulty. Replace filler cap. |